33
DESCRIPTION of ESP101 modication: The wiring modication (interconnect plug reversal) redirects the control signal
from the ESP-101 internal solenoid, to the pins within the torch connection panel receptacle. The control signal is then
diverted to the solenoid within the Remote Junction Box.
The hose modication (solenoid air bypass) directs the system air supply to the solenoid within the Remote Junction Box.
This ensures air at a sucient pressure is immediately available to the PT-37 torch.
SECTION 3 INSTALLATION
A. ESP-101 Modications
Remove the top and right side panel of the power supply.
1. Redirection of solenoid control wiring:
a. Locate, disconnect and move the solenoid interconnect plug as
shown.
2. Air ow by-pass of internal solenoid:
a. Locate and remove the included supplied air coupling.
b. Disconnect both air hoses from the input and output of the solenoid, by pushing ring inward and
pulling hose.
Reverse Trigger and Solenoid
Interconnect plugs
(a) Supplied Air Coupling
(b) Pushing ring inward -
pull hose out of
connector
From
PANEL
RECEPTACLE
SOLENOID INTERCONNECT (LOWER)
From
SOLENOID
CONTROL
To SOLENOID
Figure 3-8. Interconnect Move