EMR User's Guide
High Density Modular Audio Router (AES, Analog, MADI, TimeCode, Data)
MODULE UPGRADES Revision 1.8 Page 135
8. At the “FTP>” prompt, type “put x.bin”, where x represents the name of the application (.bin) file or
drag and drop the file to FTP prompt.
Note: If the application file is not local to where you are performing the FTP, then
include the path with the name or drag and drop the file to FTP prompt:
(e.g.: “put c:\temp\emr\firmware.bin”)
9. Once the upgrade is complete, the card needs to be rebooted manually. Do not remove the card
during this process or it could corrupt the application code.
7.2.3.2. Serial Upgrade Method
The 3000FC and EMX-FC are upgraded via the configuration serial port (J7) near the front of the card.
1. Turn off the EMR frame with the FC card that is to be upgraded.
2. Connect the 7700PB serial upgrade cable supplied with the EMR frame to the J7 on the front edge
of the FC card and connect the other end of this cable to a serial port on a PC with a serial terminal
program.
3. Place a jumper across pins 1 and 2 on J7 (“Upgrade Mode”).
4. Set up the serial communication properties for the COM port as follows:
COM: Select the COM port
Bits per second: 115200
Data bits: 8
Parity: None
Stop bits: 1
Flow control: None
5. Power on the EMR frame with the FC card installed.
6. When the FC card boots up, the following information will be printed on the terminal screen:
EVERTZ MCF5272 MONITOR 2.3 BUILD 3 (66 MHZ)
COPYRIGHT 1997, 1998, 1999, 2000, 2001, 2002 EVERTZ MICROSYSTEMS LTD.
28F160C3B FLASH DETECTED
BRD=3000FC
MODEL=BA3000FC
PROD=3000FC
FRAME=3000FR
UPGRADE JUMPER INSTALLED
UPLOAD FILE NOW, CONTROL-X TO CANCEL
7. To upload the FC with the new application code, use the send file function in the terminal software.