9 05 2013 4365 00
The sterilisation is performed by means of sterilising
products.
- Dip the parts for approx. 20 minutes in a recipient con-
taining the previously prepared sterilising solution;
- Reinstall the conveyors and the water funnels;
- Reinstall the powder deposit drawers and the powder
funnels after having carefully rinsed and dried them.
After installing the components it is however neces-
sary:
- Wash the mixer and add a few drops of the sterilising
solution into the various funnels.
- Once the sterilisation has been performed, rinse the
components well in order to remove any possible resi-
due of the solution used.
All the operations which require the machine to be
3
4
5
2
1
Fig. 8
1- Powder funnel
2- Water conveyor
3- Mixer fan
4- Powder nozzle
5- Inlet nozzle
6- Mixer fixing flange
- Open the cover of the mixer dispensing cell and lift the
powder nozzles up to the end stop;
- Remove the powder funnels, the water conveyors, the
powder deposit funnels and the mixer motor fans from
the mixers;
- The fans can be removed by simply pulling gently to
free them;
Fig. 9
- Wash all the components with sterilising products (fol-
low the dosage indicated by the manufacturer), being
careful to mechanically remove the visible residues
using brushes if necessary