2-4 Sampling Function
2-4-1 Unknown Unit Weight of a Weighed Object
1. Place the sampling object on platter:
.
Weight on platter
2. Enter the quantity of the sample on platter:
.
Weight on platter Enter the sampling quantity
NOTE:
The number of quantity column will flash 6 seconds. If the user doesn’t press the
SAMPLE
key before flashing is over, the scale will complete the unit weight setting
procedure automatically after flashing. The scale will also take the number that inputted in
unit weight column as the unit weight of object to calculate the quantity of object shown in
quantity column.
3. Press
SAMPLE
key while total column number is flashing:
.
Weight on platter
4. After stable, the scale finishes sampling and enters into counting mode.
.
.
Stable
Weight on platter Unit weight of object Enter sampling quantity
2-4-2 Known Unit Weight of a Weighed Object
1. Enter known unit weight of object intended to weigh:
0
.
.
Stable
Unit weight of object intended to weigh
2. Press
UNIT WEIGHT
key to complete unit weight setting and enter into counting mode:
0
.
.
Stable
Unit weight of object intended to weigh