Section 3 Pilot’s Operating Handbook
Emergency Procedures EXTRA 500
3-36 26. January 2011
6 Emergency Extension
Item Condition
Airspeed 110 KIAS
LANDING GEAR DN
GEAR CTRL Circuit Breaker Pull
Gear Operation Lights
Check illumination
(three greens)
Land as soon as practical
If still no three greens:
Item Condition
Hydraulic System
Reactivation
Perform
7 Hydraulic System Reactivation
Item Condition
HYDR Circuit Breaker Check in
GEAR-CTRL Circuit Breaker Push in
Important
Landing should be performed by using one of the landing
emergency procedures.
Land as soon as practical
Warning
If no three green lights and thus landing gear is not locked
collapsing of landing gear is possible any times!
Support aircraft before working on the landing gear.
Landing Gear
Hydraulic Actuator
(Prior BATT OFF)
Lock with locking device