Pilot’s Operating Handbook Section 3
EXTRA 500 Emergency Procedures
26. January 2011
3-65
LANDING GEAR; DN
2 GEAR WARN r (without aural and gear retracted)
This warning (without aural) means the gear is not fully
retracted.
Airspeed; Reduce below 140KIAS
To prevent damage of landing gear and gear doors.
LANDING GEAR; Check UP
HYDR Circuit Breaker; Check in
GEAR-CTRL Circuit Breaker; Check in
Hydraulic Pump; Runs periodically
If GEAR WARN still illuminated:
Caution Do not attempt to retract landing gear further if it fails to
retract during first attempt.
LANDING GEAR; DN
Land as soon as practical
3 GEAR WARN r (without aural and gear extended)
This warning (without aural) means the gear is not extended.
For full extension the ‘three greens’ can be checked.
Gear Operation Lights; Check illumination
(three greens)
If no three greens:
No Three Greens Procedure; Perform
4 HYDRAULIC PUMP y
This caution means the hydraulic pump (landing gear system) is
energized.
Runs continuously ; Check
HYDR Circuit Breaker; Pull
Airspeed; Reduce to max. 140 KIAS
Note
Landing gear will now slowly extent, which is indicated by the
red GEAR WARN light on the annunciator panel.
Land as soon as practical
Emergency Extension; Perform