Section 4 Pilot’s Operating Handbook
Normal Procedures EXTRA 500
4.7.q Balked Landing
When a balked landing is necessary, set power lever to Max
Power (111 % Torque). The aircraft will climb even in landing
configuration and pitch is only slightly affected by change of
power setting. After setting flaps to 15° normal climb can be
continued.
The following procedure apply:
Power Lever; MAX POWER (111 % Torque)
TOT; Monitor < 81
Condition Lever; MAX PROP RPM
Aircraft; Check positive climb
LANDING GEAR; UP
FLAPS;
Above 74 KIAS 15°
FLAPS; Above 90 KIAS UP
4.7.r Engine Shutdown
Power Lever;
GRD IDLE (at least 2 minutes)
ENV AIR; OFF
AVIONICS; OFF
Lights; OFF
STDBY ALT; OFF
GEN; OFF
Condition Lever; FUEL OFF
BATT; OFF
PARKING BRAKE;
Set as required
4.7.s Rain
Note Aircraft flight characteristics do not change when flying in
rain. However, the stall speeds will be 3 to 5 knots higher
than the given ones.
4-40 26. January 2011