the relays when the deactivation temperature is reached. Both
sensors are monitored independently. The windshield heating
temperature is between 20 °C and 40 °C.
When the windshield is actively heated the green advisory
WINDSHIELD HEAT ON is illuminated.
Failures in the system like broken wires, short circuits or an
overheat is indicated by illumination of a red WINDSHIELD
HEAT FAIL warning light on the annunciator panel.
Important In case the red WINDSHIELD HEAT FAIL warning light
illuminates on the annunciator panel, the system should be
switched
OFF immediately.
7.30 Avionics
Note For standard avionic equipment refer to the equipment list
presented in Section 6 of this POH, while for description of
avionics, refer to Section 9 of this POH.