Pilot’s Operating Handbook Section 3
EXTRA 500 Emergency Procedures
26. January 2011
3-49
necessary for keeping sight. Nevertheless, in any case try to
shut down engine as soon as possible.
After landing area is selected and safe approach established:
Power Off Landing; Perform ASAP
4 Engine Fire in Flight
If engine fire occurs during normal flight and can not be
extinguished, immediate landing on a suitable landing area is
recommended.
Warning It may be necessary to use engine power as long as possible
for safe approach to selected landing site. Sideslip aircraft if
necessary for keeping sight. Nevertheless, in any case try to
shut down engine as soon as possible.
After approaching selected landing size:
Power Off Landing; Perform ASAP
5 Electrical Fire, Smoke or Fumes in Flight
If cabin fire, smoke and/or fumes are detected, try to identify
and isolate source. Generally, the following procedure applies:
Note The severity of the electrical fire and the flight conditions
will determine how much of the aircraft electrical systems
will be cut off.
STDBY ALT; Check ON
GEN; OFF
EMERGENCY; ON
BATT; OFF
If source is known:
Faulty Equipment Circuit Breaker; Pull
BATT; ON
EMERGENCY; OFF
GEN; ON
Cabin Ventilation; As required
Land as soon as practical
Aircraft; After landing Abandon
If source is unknown:
Land ASAP