Pilot’s Operating Handbook Section 905
EXTRA 500 SHADIN MINIFLO-L
905.4.b Preflight Check (amplified)
ENTER/TEST; Press
Note Pressing and holding the ENTER/TEST button activates an
internal test sequence. An
8 appears in all parts of display
for about 10 seconds. If the test is completed,
6ooD appears
on the display. If
bAd appears, a defect in the system
occurs. Corrective measures must be carried out.
Activating the test sequence with running engine will result
in a loss of fuel measurements for 18 seconds.
If aircraft is refueled e.g. after intermediate landing, the
following correction of fuel quantity value is envisaged:
Note If no refueling during intermediate stop, no action
concerning programming the computer is required.
To add fuel:
Item; Condition
REM/USED; LIT. REM and hold
ENTER/TEST; Press and hold until
figure to be entered is reached
REM/USED; Release
REM/USED; LIT. REM to verify value
To subtract fuel:
Item; Condition
REM/USED; LIT. USED and hold
ENTER/TEST; Press and hold until
figure to be entered is reached
REM/USED; Release
REM/USED; LIT. REM to verify value
905.4.c Correction of input errors:
If a mistake is made when programming the maximum amount
of usable fuel so that it exceeds the correct value, switch and
hold the
REM/USED switch in the LIT. USED position and press
the
ENTER/TEST button at the same time. The LIT. USED
value will disappear and remaining fuel value (LIT. REM) will
26. January 2011
905-5