Section 3 Pilot’s Operating Handbook
Emergency Procedures EXTRA 500
3-14 26. January 2011
5 Electrical Fire, Smoke or Fumes in Flight
Note The severity of the electrical fire and the flight conditions
will determine how much of the aircraft electrical systems
will be cut off.
Item Condition
STDBY ALT Check ON
GEN OFF
EMERGENCY ON
BATT OFF
If source is known:
Item Condition
Faulty Equipment
Circuit Breaker
Pull
BATT ON
EMERGENCY OFF
GEN ON
Cabin Ventilation As required
Land as soon as practical
Aircraft
After landing
Abandon
If source is unknown:
Item Condition
Land ASAP
If required:
Item Condition
PRESS DUMP
Transponder
EMERGENCY
Mayday Call Transmit
Emergency Descent Perform to safe altitude
Land ASAP