3.4.l Electrical System Malfunctions
Note In case of a generator failure, the load bus will be
automatically shed.
1 GENERATOR FAIL r
Item Condition
GEN
RESET
(hold for approx. 2 seconds
and back to
ON)
If GENERATOR FAIL extinguishes:
Item Condition
VDC
Check 28
GEN AMPS
Check indication
Flight Continue
If GENERATOR FAIL still illuminates:
Item Condition
AVIONICS OFF
Flight Leave icing conditions
ICE OFF
PROP OFF
BOOTS OFF
WINDSH OFF
ENGINE START IGN OFF
STANDBY ALTERN ON
Check illuminated
no specific procedure required
Note
Battery and standby alternator supply is limited to at least
30 minutes.
In case a load from the load bus is necessary:
Item Condition
All load bus Circuit Breakers Pull
Needed Circuit Breakers Push in
BUS TIE Circuit Breaker Push in