Summit X670 Series Switches
Summit Family Switches Hardware Installation Guide
479
Power: Summit X670-48x
Summit X670-48x (AC Power Supply)
Nominal input ratings 100 to 240 V , 50/60 Hz, 2.5 A
Input current 2.25 A @ 100 V (low-line)
0.9 A @ 240 V (high-line)
Heat dissipation 225 W, 768 BTU/hr
Power consumption 225 W, 768 BTU/hr
Summit X670-48x (DC Power Supply)
Nominal input ratings 48 to 60 V , 5.0 A
Input current 4.25 A @ 48 V (low-line)
3.35 A @ 60 V (high-line)
Heat dissipation 210 W, 717 BTU/hr
Power consumption 210 W, 717 BTU/hr
Power: Summit X670V-48x
Summit X670V-48x with No Installed VIM (AC Power Supply)
Nominal input ratings 100 to 240 V , 50/60 Hz, 3.75 A
Input current 3.0 A @ 100 V (low-line)
1.2 A @ 240 V (high-line)
Heat dissipation 300 W, 1,024 BTU/hr
Power consumption 300 W, 1,024 BTU/hr
Summit X670V-48x with VIM4-40G4X Module (AC Power Supply)
Nominal input ratings 100 to 240 V , 50/60 Hz, 3.75 A
Input current 3.4 A @ 100 V (low-line)
1.4 A @ 240 V (high-line)
Heat dissipation 340 W, 1,161 BTU/hr
Power consumption 340 W, 1,161 BTU/hr
Summit X670V-48x with No Installed VIM (DC Power Supply)
Nominal input ratings 48 to 60 V , 7.5 A
Input current 5.7 A @ 48 V (low-line)
4.6 A @ 60 V (high-line)
Heat dissipation 280 W, 956 BTU/hr
Power consumption 280 W, 956 BTU/hr
Summit X670V-48x with VIM4-40G4X Module (DC Power Supply)
Nominal input ratings 48 to 60 V , 7.5 A
Input current 6.85 A @ 48 V (low-line)
5.45 A @ 60 V (high-line)
Heat dissipation 330 W, 1,126 BTU/hr
Power consumption 330 W, 1,126 BTU/hr
Power: Summit X670V-48t
Summit X670V-48t with No Installed VIM (AC Power Supply)
Nominal input ratings 100 to 240 V , 50/60 Hz, 4.0A
Input current 3.3 A @ 100 V (low-line)
1.41 A @ 230 V (high-line)
Table 90: Summit X670 Series Switch Technical Specifications (Continued)