9.3.2 Temperaturkurve für den Kühlbetrieb
KLIMAKURVEN (WTS) KÜHLBETRIEB
T4 (Außenlufttemperatur) [°C]
-10 14 15 21 22 29 30 46
id Klimakurve
Typ von auf der
Fernbedienung aus-
gewähltem Abnehmer
Eingestellte
Klimakurven
T1S oder T2S
(Wassersollwert Anlage) [°C]
16,0 16,0 11,0 11,0 8,0 8,0 5,0 5,0 1
Gebläsekonvektor C1
17,0 17,0 12,0 12,0 9,0 9,0 6,0 6,0 2
18,0 18,0 13,0 13,0 10,0 10,0 7,0 7,0 3
19,0 19,0 14,0 14,0 11,0 11,0 8,0 8,0 4
20,0 20,0 15,0 15,0 12,0 12,0 9,0 9,0 5
21,0 21,0 16,0 16,0 13,0 13,0 10,0 10,0 6
22,0 22,0 17,0 17,0 14,0 14,0 11,0 11,0 7
23,0 23,0 18,0 18,0 15,0 15,0 12,0 12,0 8
20,0 20,0 18,0 18,0 17,0 17,0 16,0 16,0 1
Bodenheizung oder
Heizkörper
C2
21,0 21,0 19,0 19,0 18,0 18,0 17,0 17,0 2
22,0 22,0 20,0 20,0 19,0 19,0 17,0 17,0 3
23,0 23,0 21,0 21,0 19,0 19,0 18,0 18,0 4
24,0 24,0 21,0 21,0 20,0 20,0 18,0 18,0 5
24,0 24,0 22,0 22,0 20,0 20,0 19,0 19,0 6
25,0 25,0 22,0 22,0 21,0 21,0 19,0 19,0 7
25,0 25,0 23,0 23,0 21,0 21,0 20,0 20,0 8
4
6
8
0
2
4
6
8
0
2
4
-10 0 10 20 30 40 50
COOLING MODE (climatic curves set C1)
1
2
3
4
5
6
7
8
1 2 3 4
5 6 7 8
4
6
8
0
2
4
6
-10 0 10 20 3 0 40 50
COOLING MODE (climatic curves set C2)
1
2
3
4
5
6
7
8
1 2 3 4
5
6
7 8
Kühlmodus (Klimakurve auf C1 eingestellt)
Kühlmodus (Klimakurve auf C2 eingestellt)
Vom Benutzer einstellbare Klimakurve 9 im Kühlbetrieb
Die Klimakurve 9 wird durch 4 vom Benutzer einstellbare Parameter bestimmt (T4C1, T4C2, T1SETC1, T1SETC2, siehe „9.2 Tabelle der Betriebsparameter“ auf Seite 379).
T4C1
T4C2
T1SETC
2
T1SETC1
T4
T
1S (T1S2)
Abb. 40 - Klimakurve 9 im Kühlbetrieb