A.1 TECHNICAL SPECIFICATIONS
General specifications
Protection class
(as per DIN 40050)
Temperature during
• operation
• storage/transport
Chemical resistance
IP 65
- 5
o
C . . . +50
o
C
-20
o
C . . . +60
o
C
See Festo Pneumatic
Catalogue (resistance table)
Vibrations
(as per DIN/IEC 68
part 2-6 and
IEC 721/part 2-3)
• transport
• operation/use
Shock
(as per DIN/IEC 68
part 2-27 and IEC 721)
3.5 mm distance at 2-8 Hz
1 g acceleration at 8-25 Hz
0.35 mm distance
at 25-57 Hz
5 g acceleration
at 57-150 Hz and
1 g acceleration
at 150-200 Hz
30 g at 11 ms
Electromagnetic
compatibility (EMC)
• Resistance to
interference
tested as per
EN 50082-2
• Radio interference
suppression
tested as per EN 55011
Limit value
severity A
*)
*) The valve terminal with FB6-03/05 can also be
used in a residential environment with individual
authorization (residential, business, commercial
environment, small firms).
Protection against
electric shock
(protection against direct
and indirect contact as
per EN 60204-1/IEC 204)
PELV power unit
(protected extra low
voltage)
VIFB6- 03/05 Appendix A
9809c A-3