Basic rule 2
If only valves are used, the address assignment
will be as described in basic rule 1.
PLEASE NOTE
•
Maximum 26 valve solenoid coils (type 03)
or 24 valve solenoid coils (type 05) can be
addressed.
•
Rounding of the last two positions
on the valve side is not necessary.
•
Valve terminals without input modules
do not require a configuration for the inputs.
The status bits are not therefore available.
Basic rule 3
If only electrical I/Os are used, the address
assignment will be as described in basic rule 1.
PLEASE NOTE
•
Counting begins immediately
to the left of the node.
•
Rounding of the last two positions
on the valve side is not necessary.
•
When all locations are fitted, the terminal
has 64 inputs (60 digital inputs and 4 status
bits) or 48 digital outputs.
VIFB6 - 03/05 4. Commissioning
9809c 4-13