Basic rule 2
If only valves are used, the address assignment
will be as described in basic rule 1.
PLEASE NOTE
Maximum 26 valve solenoid coils (type 03)
or 24 valve solenoid coils (type 05) can be
addressed.
Rounding of the last two positions
on the valve side is not necessary.
Valve terminals without input modules
do not require a configuration for the inputs.
The status bits are not therefore available.
Basic rule 3
If only electrical I/Os are used, the address
assignment will be as described in basic rule 1.
PLEASE NOTE
Counting begins immediately
to the left of the node.
Rounding of the last two positions
on the valve side is not necessary.
When all locations are fitted, the terminal
has 64 inputs (60 digital inputs and 4 status
bits) or 48 digital outputs.
VIFB6 - 03/05 4. Commissioning
9809c 4-13