4.2.2 Bus configuration without CMD software
Logical addressing
PLEASE NOTE
ID-CODE
Configure a valve terminal as follows:
- valve terminal only with
outputs
1)
with
Ident code 1
- valve terminal only with
inputs
with
Ident code 2
- valve terminal with
inputs and outputs
1)
with
Ident code 3
Process data channel
The number of inputs and/or outputs must
be rounded up to the next word limit. If the
number of input bits differs from the number
of output bits, the larger number is decisive
for entering the process data channel bits.
Observe also that the status bits of a valve
terminal with inputs occupy an additional
four inputs.
1)
Valve coils and/or electrical outputs
VIFB6 - 03/05 4. Commissioning
4-24
9809c