5. Testing parts
5-5
Festo P.BE-CB-COMP-EN en 1102d
5. Check the correct output at the output positions for good,
bad or incorrectly oriented parts with as many inspection
partsaspossible.
6. On the basis of the sample parts, check the inspection
parts with regard to their grading. If you have also tested
faulty parts, check whether these have actually been
recognized as bad.
If too many good parts have been graded and sorted out
as “Bad”:
S Increasethetolerance(seeChapter5.3)
S Repeat the Teach procedure with more sample parts,
using the conveyor device intended for automatic
mode (see Chapter 4).
7. Note the displays on the Checkbox.
When a conveyed part is registered, the status display
lights up briefly.
The display shows for 1.5 seconds:
A...
#...
The evaluation of the inspection part deviation A
(Chapter 6.4.2)
The evaluation of the inspection part orientation #
if more than one orientation has been learnt
(Chapter 6.4.3).
If the quality check and position recognition for the parts
assortment are not satisfactory, you can use additional
operating parameters and tools with CheckOpti in order to
optimize the test results. Please consult your technical
advisor.