3 Holder systems
18 © Festo Didactic 759614
3.2.2 Commissioning
Warning
When the mains cable is plugged in, voltage is present at the mains switch as far as the power
supply unit (110/230 V AC). Assembly work must only be carried out when the power supply plug is
unplugged.
1. Assemble the required simulation plates and 4 mm connection plates if applicable.
2. Connect the EduTrainer® PLC to the laboratory power supply.
3. Switch on the mains switch.
3.2.3 Technical data
Electrical/Mechanical
Operating voltage
110 V – 230 V AC
50 – 60 Hz
Input current 1.3 A – 0.65 A AC
Output voltage 24 V DC ± 3%
Fuse 3.15 A slow-blowing
Output current Max. 4.5 A
Connection
4 mm safety sockets
3-pin plug for internal supply to modules
Front-plate width, power supply 6 HP (1 HP = 1/5“ = 5.08 mm)
Size 1 297 mm x 305 mm x 120 mm (60 HP)
Size 2 297 mm x 458 mm x 120 mm (90 HP)
Maximum PLC width/height, size 1 295 mm/125 mm
Maximum PLC width/height, size 2 448 mm/125 mm
CE marking
in accordance with low voltage directive
in accordance with EU-EMC Directive
Interference emission tested to EN 61000-6-3
Interference immunity tested to EN 61000-6-1
Subject to change