1 For your safety
8 © Festo Didactic 759614
Risk of fatal injury from connecting power supply units in series
Contact voltages > 25 V DC are no longer permitted.
Voltages > 120 V DC can be fatal to the touch.
Do not connect power sources in a row.
The ventilation slits of power supply units must not be covered. The devices must be placed on hard,
flame-resistant surfaces so that the air can enter the devices unhindered. The devices are primarily
cooled by convection.
When working under electrical voltage, use only expressly suitable tools.
Set the device up so that activation of switches and disconnectors is not rendered difficult.
Risk of fatal injury from electrical shock
Protect the outputs of the power supply units (output sockets/terminals) and cables connected to them
from direct contact.
Use only cables with adequate insulation and/or electric strength.
Use safety sockets with touch-safe contact points.
Safe operation of the device is no longer possible in the case of
visible damage,
faulty operation,
inappropriate storage or
inappropriate transport.
Switch off the power immediately.
Protect the device from being unintentionally turned on again.
Disconnect the power before making or breaking electrical connections.
Use only extra-low voltages (max. 24 V DC).
Unused slots of the holder system must be covered with 19" blanking plates.
Unused cable entries of the holder system must be covered with covers included with
the holder system.