5. Maintenance and conversion
5-27
Festo P.BE-MPA-EN en 1108e
MPA-S valve terminal with multi-pin plug connection
Dismantling Proceed as follows:
1. Loosen the electrical and pneumatic connections and
remove the MPA-S valve terminal from the mounting
surface (see this Chapter “Dismantling the MPA-S valve
terminal”.
2. Place the MP A-S valve terminal on a flat working surface.
3. L o osen the fastening screws between the multiple
connector plate and the pneumatic sub-bases in the
sequence 321(see foll owing diagram).
4. Then loosen and remove the fastening screws.
1
23
Fig. 5/13: Position of the screw connectors on the sub-base
5. Pull the multiple connector plate away from the
pneumatic sub-bases.