5. Maintenance and conversion
5-28
Festo P .BE-MPA-EN en 1108e
Mounting Proceed as follows:
1. Make sure the seals are not damaged. Replace the seals if
they are damaged.
2. Place the seal onto the guide pins of the multiple
connector plate.
1 Multiple
connector plate
2 Guide pins
3 Seal
4 Pneumatic
sub-base
21
234
Fig. 5/14: Mounting the multiple connector plate
3. Pull the multiple connector plate away from the
pneumatic sub-bases. Make sure that the seal and the
components are correctly positioned.