5. Maintenance and conversion
5-35
Festo P.BE-MPA-EN en 1108e
MPA-S valve terminal with CPX terminal
Note
Maximum 16 M PA sub-bases are permitted on the MPA-S
valve terminal with CPX terminal and electric supply plate.
Without the electric supply plate 8 MPA sub-bases are
permitted.
Necessary components
For extension you will require:
Components
MPA-S valve termin al with ...
CPX terminal Multi-pin plug
connection
One sub-base per:
–MPA1:4valvepositions
–MPA2:2valvepositions
VMPA1-FB-AP-4-1
1)
or VMPA1-FB-AP-4-1-...
2)
VMPA2-FB-AP-2-2
1)
or VMPA2-FB-AP-2-2-...
2)
One electronics module per sub-base see Tab. 5/3 see Tab. 5/4
Valve or blanking plates:
– MPA1: 4 per sub-base
– MPA2: 2 per sub-base
VMPA...-M1H-...
VMPA...-M1H-...
If necessary, additional pneumatic supply plate:
– With exhaust plate
– With flat plate silencer
VMPA...-FB-SP
VMPA...-FB-SPU
If necessary, additional electric supply plate:
– With plug M18
– With plug 7/8” (4-pin)
– With plug 7/8” (5-pin)
VMPA-FB-SP-V
VMPA-FB-SP-7 /8-V-4POL
VMPA-FB-SP-7 /8-V-5POL
----
For e very added sub-base or pneumatic supply
plate, the appropriate interlinking boards:
– Interlinking board for sub-base
– Interlinking boards for pneumatic supply plate
VMPA1-FB-EV-AB
VMPA1-FB-EV-V
see Tab. 5/5