A. Technical appendix
A-10
Festo P .BE-MPA-EN en 1108e
Note
The fittings of the pneumatic ports cause a reduction in the
nominal flow rate of the valves.
Pneumatics
MPA1
I.C.
1)
Valve Standard nominal flow rates [l/min],
measured with screw connector QS-M7-6-I
1 } 2or1} 4
2)
2 } 3/5 or 4 } 3/5
2)
M, J
B
G
E
H, HS
K, KS
N, NS
W, X
D, DS
I
5/2-way
5/3-way, pressurised
5/3-way, closed
5/3-way, exhausted
2 x 3/2-way
2 x 3/2-way
2 x 3/2-way
1x3/2way
2x2/2-way
2x2/2-way
360
300 (220)
3)
320
240
300
230
300
255
230
260
360
270
320
240 (200)
3)
305
310
300
295
----
260
Valve switching times in [ms]
(measuring method 0 - 10 % as per FN 942032)
On/changeover Off
M
J
B, G, E
H, K, N
HS, KS, NS
W, X
D, I
DS
5/2-way, single solenoid
5/2-wa y, double solenoid
5/3-way valves
2 x 3/2-way
2 x 3/2-way
1x3/2way
2x2/2-way
2x2/2-way
10
10/15
10
10
14
10
10
14
20
---
35
20
16
20
20
16
1)
I.C. = Identificationcode of th e valve sub-base
2)
Flow direction 1 } 4or4} 3/5 not with valves having Ident. codes I, W and X.
3)
Values for the mid-position a re quoted in brackets
Tab. A/5: Nominal flow rates and valve switching times for MPA1