A. Technical appendix
A-11
Festo P.BE-MPA-EN en 1108e
Pneumatics MPA2
I.C.
1)
Valve Standard nominal flow rates [I/min] measur e d:
Without fitting With fitting
QS G1/8-8-I
1 } 2or
1 } 4
2)
2 } 3/5 or
4 } 3/5
2)
1 } 2or
1 } 4
2)
2 } 3/5 or
4 } 3/5
2)
M, J
B
G
E
H, N
K
W, X
D
I
5/2-way
5/3-way, pressurised
5/3-way, closed
5/3-way, exhausted
2 x 3/2-way
2 x 3/2-way
1x3/2way
2x2/2-way
2x2/2-way
700
520
630
610
560
500
500
680
680
700
650 (350)
3)
630
440 (350)
3)
490
560
590
----
500
670
510
610
590
550
500
470
650
650
670
600 (350)
3)
610
420 (350)
3)
480
540
560
----
500
Valve switching times in [ms]
(measuring method 0 - 10 % as per FN 942032)
On/changeover Off
M
J
B
G
E
H, K, N
W, X
D, I
5/2-way, single solenoid
5/2-way, double solenoid
5/3-way, pressurised
5/3-way, closed
5/3-way, exhausted
2 x 3/2-way
1x3/2way
2x2/2-way
15
9/22
11 / 23
10 / 21
11 / 23
8
13
7
28
---
46
40
47
28
22
25
1)
I.C. = Identificationcode of th e valve sub-base
2)
Flow direction 1 } 4or4} 3/5 not with valves having Ident. codes I, W and X.
3)
Values for the mid-position a re quoted in brackets
Tab. A/6: Nominal flow rates and valve switching times for MPA2