5.3 Electrics
DANGER
Risk of death in case of an interrupted grounding conductor!
– The grounding conductor (yellow-green) must not be interrupted, neither
inside nor outside of the device.
– The insulation of the grounding conductor must never be damaged or
removed.
Risk of death from connecting power supply units in series!
Contact voltages higher than 25 V AC or 60 V DC are not permissible.
Coming into contact with voltages of greater than 50 V AC or 120 V DC may be
fatal.
– Do not connect voltage sources in series.
Risk of death due to electric shock!
Protect the outputs of the power supply units (output sockets/terminals) and
cables connected to them from direct contact.
– Use only cables with adequate insulation and electric strength.
–
Use safety sockets with fully shrouded contact points.
WARNING
Disconnect from all sources of electric power!
– Switch off the power supply before working on the circuit.
– Please note that electrical energy may be stored in individual components.
Further information on this issue is available in the datasheets and operating
instructions included with the components.
– Warning!
Capacitors inside the device may still be charged even after being
disconnected from all sources of voltage.