General operation
Seite/Page 20 - Kapitel/Chapter 3: General operation 20.10.22
3.4.2.1 Priming the fuel system (»Prime fuel«)
To prime the fuel system, the Panda iControl3 offers the option of separately activating the fuel pump. In the set-up
submenu »Generator«, select the menu item "Prime fuel" and confirm your selection using the start/stop button.
Fig. 3.4.2-1: Submenu »Generator«, highlighted *Prime fuel*• Select *Prime fuel* and confirm with the start/stop button.
Fig. 3.4.2-2: Screen for priming fuel• Actuate the cursor-up button (Enable) to switch the fuel
pump on.
• Actuate the cursor-down button (Disable) to switch the fuel
pump off.
• Actuate the start/stop button (Back) to go back to set-up
submenu »Generator«.
3.4.2.2 Resetting the service interval (»Service«)
Note!As the indication of operating hours remaining until the
next service interval can be reset at any time, it serves
only as an orientation guide. The service intervals shall
be implemented using the actual operating hours and
shall be properly documented in the service log of the
generator.
Note!With the dynamic operation hours the service interval
can be raised up to 30 % (200 h max.). Make sure that the
dynamic operation hours are not reset accidently
between the service interval.
Fig. 3.4.2.2-1: Submenu »Generator«, highlighted *Service*• Select *Service* and confirm with the start/stop button.