Warnings and error messages
Seite/Page 42 - Kapitel/Chapter 6: Warnings and error messages 20.10.22
Error messages can be acknowledged with the start/stop button, The controller will then return to stand-by mode.
6.2.2 Warning and fault thresholds
The threshold values resulting in triggering warnings and faults depend on the generator type and are compiled in
table below.
Fig. 6.2.2-1: Warning and fault thresholds for different generator types
100 Inverter overload L3 L3 Overload L3 Ueberlast
103 Universal output 1 high UOut1 overcurrent UOut1 Ueberstrom
104 Universal output 2 high UOut2 overcurrent UOut2 Ueberstrom
130 CAN communication lost BUS ERROR Bus Fehler
135 Synchronisation problem parallel inverters Inv. sync. fails Inv. sync. Fehler
136 CAN communication to external ECU lost ECU com. lost ECU Komm. verloren
138 Diagnostic Message (ECU) Engine fault Motorstoerung
142 Red Stop Lamp (RSL) Engine fault Motor Fehler
148 Error three-phase rotating field Error field rotation falsches Drehfeld
150 Init failed (no generator type is selected) Init fail Init fail
151 Watchdog Error Watchdog Watchdog
152 Inverter temperature high L1 L1 temperature high L1 Temperatur hoch
153 Inverter temperature high L2 L2 temperature high L2 Temperatur hoch
154 Inverter temperature high L3 L3 temperature high L3 Temperatur hoch
155 Inverter temperature high DC link DC temperature high DC Temperatur hoch
163 Inverter DC link overload DC Overload DC Ueberlast
164 Inverter DC link overvoltage DC Overvoltage DC Ueberspannung
Generator type Warning/fault Warning threshold Fault threshold
5000i marine Cylinder head temperature
Delay
85 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
1 s
75 °C
1 s
5000i vehicle Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
100 °C
1 s
105 °C
1 s
P8000i / P10000i marine Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
1 s
75 °C
1 s
P8000i / P10000i vehicle Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
100 °C
1 s
105 °C
1 s
Error
code
Meaning Error Message English Error Message German

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fischer Panda iControl3 and is the answer not in the manual?

Fischer Panda iControl3 Specifications

General IconGeneral
BrandFischer Panda
ModeliControl3
CategoryController
LanguageEnglish

Related product manuals