EasyManua.ls Logo

Fischer Panda iControl3 - Annex; Technical Data for iControl3 Systems

Fischer Panda iControl3
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Warnings and error messages
20.10.22 Kapitel/Chapter 6: Warnings and error messages - Seite/Page 43
P8-P50 marine Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
1 s
75 °C
1 s
P8-P50 vehicle Cylinder head temperature
Delay
95 °C
5 s
100 °C
5 s
Winding temperature
Delay
160 °C
5 s
165 °C
5 s
Exhaust manifold temperature
Delay
100 °C
1 s
105 °C
1 s
P15000i marine Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
2 s
75 °C
2 s
P15000i vehicle Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
95 °C
2 s
100 °C
2 s
P25i Marine Cylinder head temperature
Delay
90°C
5s
95°C
5s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70°C
2 s
75°C
2 s
P25i vehicle Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
100 °C
2 s
105 °C
2 s
P45i marine 230V/400V Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
80 °C
2 s
85 °C
2 s
P45i vehicle 230V/400V Cylinder head temperature
Delay
98 °C
5 s
105 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
100 °C
2 s
105 °C
2 s
P45i marine 3x230V Cylinder head temperature
Delay
98 °C
5 s
105 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
2 s
75 °C
2 s
Generator type Warning/fault Warning threshold Fault threshold

Table of Contents

Related product manuals