User’s manual FlexGain Plex, V2
Version 1.3 52 from 99
2.2.2.5 Fault and maintenance management menu.
After typing “2” in the main menu and pressing enter, the following message will be
displayed:
PLEX2_01_FMM>
Type <H> to list all available commands in the fault and maintenance sub-menu::
PLEX2_01_FMM>H
ACO Activate/deactivate alarm cutoff
ALARM Display module alarm status
DATE Display/set the system date
EDL Activate/deactivate V35 equipment digital loopback
H(HELP) Display help information
LDL Activate/deactivate E1 local loopback
M(AIN) Return to main menu
PCMLED Assign PCM-led to PCM stream
RDL Activate/deactivate E1 remote loopback
SETLINE Set V.35 control line state
STATUS Display module subsystems status
TIME Display/set the system time
V35CLKMODE Set V.35 clock mode
V35CLKTX Select V.35 Tx clock polarity
V35CLKRX Set V.35 input (RX) clock polarity
VERSION Display the hard'n'so’t’module versions
<ACO> command.
The <ACO> command activates or deactivates alarm relays. This allows the user to
ignore alarms and switched off external alarm signaling connected to the device via this
relay.
Command syntax:
<ACO> [ON | OFF]
where
ON switches on the alarm relay;
OFF switches off the alarm relay.
The <ACO> command without parameters displays the status of the alarm relays.
To display the help information, enter <ACO /H>.
Example:
PLEX2_01_FMM>ACO
ACO MAJOR:OFF
ACO MINOR:OFF
<ALARM> command.
The <ALARM> command displays the actual alarm status of the local device. The
command is entered without any parameters.
To display the help information, enter <ALARM /H>.