User’s manual FlexGain Plex, V2
Version 1.3 54 from 99
The <DATE> command without any parameters displays the current date.
To display the help information, enter <DATE /H>.
Example:
PLEX2_01_FMM>DATE 26.04.05
PLEX2_01_FMM>DATE
Today's date is: 26.04.05
<EDL> command.
The <EDL> command activates or deactivates the digital loop on the V.35 port.
Command syntax:
<EDL > <ON | OFF>
where
ON activates the loop;
OFF deactivates the loop.
To display the help information, enter <EDL /H>.
Example:
PLEX2_01_FMM>EDL ON
PLEX2_01_FMM>EDL OFF
<LDL> command.
The <LDL> command activates or deactivates the digital loop on the E1 port from the
output to the input of the cross-connect matrix.
Command syntax:
<LDL> [PCM1|PCM2] [ON | OFF]
where:
PCM1, PCM2 are notations of Е1 streams;
ON activates the loop;
OFF deactivates the loop.
The command without any parameters displays the status of loops on the Е1
interface.
To display the help information, enter <LDL /H>.
Example:
PLEX2_01_FMM>LDL
PCM1 local digital loopback:OFF
PCM2 local digital loopback:OFF