User’s manual FlexGain Plex, V2
Version 1.3 55 from 99
PCM3 local digital loopback:OFF
PLEX2_01_FMM>LDL PCM1 ON
PCM1 local digital loopback:ON
PCM2 local digital loopback:OFF
PCM3 local digital loopback:OFF
PLEX2_01_FMM>LDL PCM1
PCM1 local digital loopback:ON
<PCMLED> command.
The <PCMLED> command assigns E1 LED to one of PCMx streams.
The Е1 LED displays the status of only one of E1 streams, therefore, if the
<PCMLED PCM1> command is entered, the E1 LED displays the alarms (minor, major
alarms) of the first Е1 channel (PCM1). Note that the <PCMLED> command does not
affect the operation of alarm relays.
Command syntax:
<PCMLED> <PCM1|PCM2>
where:
PCM1, PCM2 are notations of Е1 streams.
To display the help information, enter <PCMLED /H>.
Example:
PLEX2_01_FMM>PCMLED PCM1
PLEX2_01_FMM>PCMLED
PCM-led assigned to PCM1
<RDL> command.
The <RDL> command activates or deactivates the digital loop on the E1 port from
the output of the transmitter to the input of the receiver.
Command syntax:
<RDL> [PCM1|PCM2] [ON | OFF]
where:
PCM1, PCM2 are notations of Е1 streams;
ON activates the loop;
OFF deactivates the loop.
The command without any parameters displays the status of the loop.
To display the help information, enter <RDL /H>.
Example:
PLEX2_01_FMM>RDL
PCM1 remote digital loopback:OFF
PCM2 remote digital loopback:OFF
PCM3 remote digital loopback:OFF
PLEX2_01_FMM>RDL PCM1 ON