FLUXUS WW 9 Start-up of the transmitter
68 UMFLUXUS_WWV1-1EN, 2018-02-28
9.3 Initialization
During an initialization (INIT) of the transmitter, the settings in the program branches Parameter and Output Options
and some of the settings in the program branch Special Funct. are reset to the default settings of the manufacturer. 
For INIT-resistant settings, see annex A.
Proceed as follows to execute an initialization:
• When switching on the transmitter: keep keys BRK and C pressed. 
• During the operation of the transmitter: press keys BRK, C and ENTER at the same time. A reset is executed. Release 
only key ENTER. Keep keys BRK and C pressed.
After the initialization, the remaining settings of the transmitter can be reset to the default settings and/or the stored mea-
sured values can be deleted.
9.4 Display
9.4.1 Main menu
The selected program branch is displayed in angle brackets and capital letters. The complete designation of the selected 
program branch is displayed in the lower line.
Select a program branch with key   and  . Press ENTER.
9.4.2 Program branches
• program branch Parameter
input of the pipe and fluid parameters
• program branch Measuring
execution of measurement steps
• program branch Output Options
setting of the physical quantity, the unit of measurement and the parameters for the transmission of measured value
• program branch Special Funct.
contains all functions that are not directly related to the measurement
After the initialization has been executed, the message INITIALISATION  DONE is dis-
played.
Select yes to reset the remaining settings to default settings or no to keep them at the cur-
rent settings.
Press ENTER.
If yes is selected, the message FACTORY DEFAULT DONE will be displayed.
Select yes to delete the stored measured values or no to keep them. Press ENTER.
This display will only be indicated if measured values are stored in the transmitter.
The main menu contains the following program branches:
• par (parameters)
• mea (measuring)
• opt (output options)
• sf (special functions)
Note! By pressing key BRK, the measurement is stopped and the main menu is selected.
Note! In this user manual, all program entries are displayed in typewriter font (Parameter). The menu 
items are separated from the main menu by a backslash "\".
  INITIALISATION
   ----DONE----
FACTORY DEFAULT?
no >YES<
Delete Meas.Val.
no >YES<
>PAR< mea opt sf
Parameter