FLUXUS WW 8 Connection
50 UMFLUXUS_WWV1-1EN, 2018-02-28
8.1 Transducers
It is recommended to run the cables from the measuring point to the transmitter before connecting the transducers to
avoid load on the connectors.
For the connection of the transducer cable to the transmitter, see section 8.1.1.
For the connection of the extension cable to the transmitter, see section 8.1.2.
For the connection of the extension cable to the junction box, see section 8.1.3.
For the connection of the transducer cable to the junction box, see section 8.1.4.
8.1.1 Connection of the transducer cable to the transmitter
For the connection of the transducer cable with SMB connectors (connection system TS, direct connection), see section
8.1.1.1.
For the connection of the transducer cable with a plastic cable jacket and stripped cable ends (connection system TS,
direct connection), see section 8.1.1.2.
For the connection of the transducer cable with a stainless steel conduit and stripped cable ends (connection system TS,
direct connection), see section 8.1.1.3.
8.1.1.1 Transducer cable with SMB connectors
Remove the left blind plug for the connection of the transducer cable (see Fig. 8.2).
Insert the transducer cable with the SMB connectors into the housing.
Fix the transducer cable by tightening the cable gland.
Connect the SMB connectors to the sockets of the transmitter (see Fig. 8.1, Fig. 8.2 and Tab. 8.1).
Note! If transducers are replaced or added, the sensor module also has to be replaced or added (see sec-
tion 8.5).
Attention! Observe the "Safety instructions for the use in explosive atmospheres" (see SIFLUXUS document).
Attention! The degree of protection of the transmitter is ensured only if the cable glands are firmly tightened and
the housing is tightly screwed.
Attention! Observe the "Safety instructions for the use in explosive atmospheres" (see SIFLUXUS document).
Fig. 8.2: Connection of the transducer cable with SMB connectors to the transmitter
AVSAV
AGN
ARS
AR
BVSBV
BGN
BRS
BR
SA1
SA2
SA3
SA4
SB1
SB2
SB3
SB4
T1a
T1b
S2 T2a
T3a
T3b
S4
T4a
T2b
T4b
T1A
T1B
S1 T2A
T3A
T3B
S3
T4A
T2B
T4B
A+
B-
P1+ P2+
P4+
P5a
P6a P7a
P3+
101
103
P1- P2-
P4-
P5b
P6b
P7b
P3-
PE
N(-)
L(+)
SMB connector
transducers
measuring channel B
transducers
measuring channel A

Table of Contents

Related product manuals