FT-107 Weighing Terminal, Technical Manual, Rev. 1.0.0, August 2019 Page 7 of 46
3. INTRODUCTION
3.1 Overview
FT-107 weighing terminal is economic and powerful state-of-the-art indicator for industrial weighing
applications like basic weighing, piece counting, checkweighing or animal weighing.
FT-107 has the capacity for 100 records.
The scales equipped with FT-107 weighing terminal can be used in all kind of industrial areas up to wet and
hygienic environments with its fast and efficient cleaning build to the international guidelines.
3.2 Specifications
24-bit Delta-Sigma ratio metric with integral analog and digital filters
0.4 μV/d (approved); 0.1μV/d (non-approved)
0 mV to +18 mV (unipolar)
up to 6.000 increment (approved);
up to 30.000 increment (industrial)
Scale Calibration and Functions
Calibration is performed with or without load cell non-linearity correction.
3 steps programmable adaptive digital filter;
4 steps programmable filter at dynamic weighing.
Taring, zeroing, auto zero tracking, motion detection, auto zero at power up,
increased resolution, unit change, temporary gross weight indication.
Basic weighing, check weighing, piece counting, animal weighing, totalization.
100 product memory at check weighing,
100 product memory at piece counting.
100 product quantity memory at piece counting.
Up to 4 load cells 350 Ω or 12 load cells 1100 Ω in parallel
4- or 6-wire technique.
Cable length: maximum 2000 m/mm² for 6-wire connection
1200 to 38400 baud rate, 8N1
1200 to 38400 baud rate, 8N1
12 VDC (with 100 – 240 VAC / 12 VDC adaptor)
12 VDC or 100 – 240 VAC, 50-60 Hz
2000mAh Li-ion, up to 36h continuous operation for single load cell /
24h for 4 x load cells
Environment and Enclosure
-15 °C to +55 °C; 85% RH max, non-condensing