Working with measurement tools17
2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to
(Set alarm on spot).
4. Push the joystick. This displays a dialog box where you can define the settings for the
alarm.
Alarm condition: The condition that triggers the alarm. Applicable values are
Above, Below, or Off.
Alarm limit: The temperature value that will be the critical condition when an alarm
is triggered or not.
Alarm sound: Applicable values are Beep or No sound.
5. Push the joystick. This closes the dialog box.
17.8.4.2 Setting up an alarm for a box, circle, or line
Note This procedure assumes that you have previously set the camera to display at
least one value (maximum, minimum, or average) in the result table.
Follow this procedure:
1. To select the measurement tool, touch the tool on the screen. The tool is now dis-
played with one or more handles.
2. Push the joystick—or touch and hold the tool. This displays a context menu.
3. Use the joystick to go to (depending on tool)
, , or (Max/Min/Avg/Alarm)
or (Graph/Max/Min/Avg/Alarm).
4. Push the joystick. This displays a submenu.
5. Select
(Set alarm).
6. Push the joystick. This displays a dialog box where you can define the settings for the
alarm.
Alarm condition: The condition that triggers the alarm. Applicable values are
Above, Below, or Off.
Select measurement: Applicable settings are the values you have previously de-
fined (Max, Min, and/or Avg).
Alarm limit: The temperature value that will be the critical condition when an alarm
is triggered or not.
Alarm sound: Applicable values are Beep or No sound.
7. Push the joystick. This closes the dialog box.
17.8.4.3 Setting up an alarm for a difference calculation
Note
You can set up an alarm for a difference calculation when defining user presets, or
when editing an image in the archive.
This procedure assumes that you have previously set up a difference calculation.
Follow this procedure:
1. To set up an alarm for a difference calculation, do the following:
If you are defining user presets, select
(Add measurement). This displays a
submenu.
If you are editing an image in the archive, select
(Measurement). This displays
a submenu.
2. Select
(Select). This displays a dialog box.
3. Select Delta. This displays a context menu.
4. Use the joystick to go to
(Set alarm on delta).
#T559954; r. AP/42311/42335; en-US
64

Table of Contents

Other manuals for FLIR T1020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FLIR T1020 and is the answer not in the manual?

FLIR T1020 Specifications

General IconGeneral
Resolution1024 × 768 pixels
Detector TypeUncooled microbolometer
Digital Camera5 MP
Laser PointerYes
Wi-FiYes
Image Frequency30 Hz
Detector Pitch17 µm
Digital Zoom1-8x continuous
Video RecordingYes
Storage MediaSD card
Spectral Range7.5 – 14 µm
Temperature Range-40 °C to +2000 °C (-40 °F to +3632 °F)
Field of View28° x 21°
Display4.3 in LCD touchscreen, 800 × 480 pixels
FocusMotorized and manual
Image ModesThermal, visual, MSX
Operating Temperature-15 °C to +50 °C
Storage Temperature-40 °C to +70 °C (-40 °F to +158 °F)
ConnectivityUSB 2.0, HDMI
Image StorageJPEG
Image FormatsJPEG
Thermal Sensitivity<20 mK at 30°C