ROTADISK Pneumatic Actuator RD & RDF
Operating Manual BA3002 EN
9 Shutdown
Page 65 of 79
9 Shutdown
9.1 Safety Information
To avoid personal injury and/or material damage, make sure that shutdown
work is performed only by qualified personnel with suitable personal protective
equipment (PPE) and suitable tools.
See chapter 2 Safety Information.
9.2 Shutting Down the ROTADISK Pneumatic Actuator
9.2.1 Prerequisites for Shutdown
Make sure that the following prerequisites are fulfilled before shutting down and
disassembling:
The owner’s specifications for shutdown and disassembly are observed.
The pipework and the ROTADISK Pneumatic Actuator are depressurised and free from
fluid residues and cooled down so that there is no danger of injury.
9.2.2 Shutting Down the ROTADISK Pneumatic Actuator
For shutting down, observe the information in the manufacturer’s documentation
(e.g. Ball Valve operating manual) of the automatic valve components.
1. Take the pipework out of operation.
2. Switch the valve (e.g. ball valve) several times so that fluid residues and
entrapped pressure can escape.
3. Make sure that there are no fluid residues or other substances in the pipework.
4. Disconnect the power and air supply from the ROTADISK Pneumatic Actuator and
its control components.
5. Dismantle the ROTADISK Pneumatic Actuator from the valve.
Shutdown is completed.