ROTADISK Pneumatic Actuator RD & RDF
Operating Manual – BA3002 EN
10 Storage
Page 67 of 79
10.2 Storing the ROTADISK Pneumatic Actuator
The following prerequisites are satisfied:
The ROTADISK Pneumatic Actuator
▪
is not connected to and has been dismantled from the valve (e.g. ball valve).
▪
is free from dirt.
▪
is dry.
1. In the case of a heavy ROTADISK Pneumatic Actuator (≥ 15 kg), strap the sling
loops of a suitable lifting gear around the body of the ROTADISK Pneumatic
Actuator or fasten the slings to the lifting eyes (if available).
2. Transport the ROTADISK Pneumatic Actuator to its storage location
( see chapter 12 Transport).
3. Place the ROTADISK Pneumatic Actuator carefully into a pallet box.
4. Ensure the following storage conditions to prolong the service life of the ROTADISK
Pneumatic Actuator:
Storage conditions for the ROTADISK Pneumatic Actuator:
Indoor areas/rooms (long-term storage):
– dry, free from dust and adequately aired
– storage temperature between +1 °C and +50 °C
– relative humidity of < 50 %
Outdoors/construction sites (short-term storage; ≤ 14 days):
– storage temperature between −10 °C and +50 °C
✓ The preparations for storing the ROTADISK Pneumatic Actuator are completed.