Section 4: Using the Model 9100: AC Current Function 4.6-11
Final Width = 215mm
4.6.5.3 Hardware Configurations
Current or Frequency Changes
When increasing or decreasing output current or frequency, using any method: if the new
current or frequency is too large or small for the present hardware configuration, then if
OUTPUT is OFF there will be no noticeable effect as the hardware reconfigures.
If OUTPUT is ON, it will be temporarily turned OFF so that the hardware can
reconfigure, then ON again at the new current. No warning is given. This interruption
should cause little disturbance to the reading on any UUT.