1.
Record inside diameter (ID). Ensure the actual pipe ID
matches the pipe ID shown on the factory calibration
certicate. If IDs do not match, refer to "Pipe Area" on
page 68.
2.
Record up/downstream straight-pipe requirements
based on Pipe ID and meter style (insertion or inline).
[refer to p. 21]
3.
The Flow Direction Indicator must point in the
direction of ow.
4.
Ensure correct probe depth setting. If using 1 ½" size
pipe, please see note on p. 24.
5.
Ensure power wiring [p. 36] properly connected.
[refer to Wiring section p. 33 for more information]
6.
Ensure remote wiring is correct if remote option
ordered.
[refer to p. 48 for more information]
7.
Verify you have the proper output signal wiring
[refer to p. 38 - p. 45 for more information]
8.
Power on the ow meter.
9.
Check the remaining ow meter settings by accessing the meter settings either through the front panel
of the display or by using the FT3 View™ software tool. Record the settings in the spaces given for
items A - E on the following page.
Use the table below as a guide while using the worksheet on the next page to record your notes.
NOTE! Please read the entire quick-start procedure before beginning installation.
ID
Outer
Diameter
(OD)
FLOW
4X = Inline
8X = Inline
15X = Insertion
Pipe ID min.
INDICATOR:
- POINT IN DIRECTION
OF FLOW
FLOW
MODEL FT2A
Gas Mass Flowmeter & Temperature Transmitter
FLOW
0.87"
(22.098mm)
L
C
4-20
FLOW
4-20
#2
Red 1
Red2
Yel 3
Wh 4
Wh 5
PULSE
TS2
TS1
1
2 3
+1
-2
+3
-4
+5
TS3
REMOTE
SENSOR
Earth Ground
24V Return
+24VDC
TS1
1
2 3
TS3
#4
#6
#3
#5
#2
#1
Black Dot Denotes Pin #1
Cable Shield
Electronics Enclosure
RED
RED
WHT
WHT
GRN
WHT
Shield
GRN
BRN
YEL
BLK
RED
Probe Sensor Wired By Fox
SENSOR
RED
BLK
BRN
WHT
GRN
1
2
3
4
5
RED
RED
YEL
WHT
WHT
Remote Enclosure
Sensor Wires
F1
F2 F3 F4
Initializing...
4-20
FLOW
TS4
24V
OUT
4-20
#2
Red2
Yel 3
Wh 4
Wh 5
PULSE
/ALM
TS1
F1
J2
1
24V, 0.75A
2 3
IN
+1
+1 -2
-2
+3
-4
+5
-6
+7
-8
TS3
REMOTE
SENSOR
+24VDC
+24VDC
4 to 20mA FLOW RATE
4 to 20mA TEMPERATURE OR
FLOW RATE
24VDC Return
Customer PLC or DCSFT3
24VDC Return
* (see important note below)
* (see important note below)
Ouick Start Guide | 6
Model FT3