EasyManua.ls Logo

Frick Vyper 700 - Control Logic Board; Filter Logic Board

Frick Vyper 700
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VYPER
VARIABLE SPEED DRIVE
OPERATION
100-210 IOM (JUL 09)
Page 55
1. J5 Connector (volt-
age input / test points
2. J8 Communications
to the logic board
(J15)
3. Power Supply “OK”
LED
4. Filter “Over-Temp”
LED
5. Run LED
6. Filter ON/OFF switch
7. E-prom
1. DC Voltage Test Points
2. 24VAC Input
3. Gate Drive Connections J8, J9 & J10
4. J12 Start Input / Run Output
5. J6 to J4 of the SCR Trigger Board
6. E-prom Chips
7. Communication Indicators RX/TX, Logic
Board to Quantum LX
8. J16 Communications Cable, Logic
Board to Quantum LX
9. Communications Indicators RX/TX,
Logic Board to Filter Board
10. J15 Communications Cable, Logic
Board to Filter Board.
11. DC Bus Voltage Input
12. J2 Remove to manually engage circula-
tion pumps and internal fans
13. JOB FLA Potentiometer
14. Frequency Switch (60/50Hz)
15. Output Current input, Phase - A, B & C
The callouts on Figures 70 and 71 point
out components, indicators and test points
that can be used to aid in maintenance
amd troubleshooting of fault codes.
Figure 70 - Control Logic Board
Figure 71 - Filter Logic
Board

Table of Contents