Fröling Heizkessel- und Behälterbau Ges.m.b.H, Industriestrasse 12, A-4710 Grieskirchen Page 21
Tel +43 (0) 7248 606-0 Fax +43 (0) 7248 606-600 info@froeling.com www.froeling.com B0430207
Do not touch the hot surface!
Hot parts and the flue pipe can cause serious burns!
Protective gloves should generally be worn when working on
the boiler.
Only operate the boiler using the handles provided for this
purpose.
Insulate the flue pipes or simply avoid touching them during
operation.
Before carrying out maintenance work on/in the boiler:
Press and hold the key for 5 seconds
Boiler follows shutdown procedure and changes to the
operating status “Burner off”
Do not open the ash doors during operation!
This may cause injury, damage and smoke!
It is forbidden to open the doors behind the insulating door
during operation!
Do not use unauthorised fuel!
Non-standard fuels can cause serious faults in combustion (e.g.
spontaneous combustion of carbonisation gases / flash fires) which
can lead to serious accidents!
Only use fuels specified in the chapter on “Permitted Uses” in
these instructions.
2.5.1 In the event of loss of electrical power
Do not open any Boiler Doors.
Do not load fuel into the boiler.
Boiler Control System automatically restarts after power fail restart.
One hour after power has returned, check system for normal
operation and compare the pressure gauge reading to initial settings.