Page 34
B0430207 I
4
4.6.2 Temperature Settings of the DHW Tank
DHW tank 01 ... 08
4.6.3 Heating Times of the DHW Tank
DHW tank 01 ... 08
Times must be set in the service mode.
4.7 Menu-Solar
4.7.1 Status Displays for the Solar System
Display
Description
Collector Temperature 80°C
Current temperature at collector.
Solar temperature storage
tank bottom 38°C
Current temperature at solar sensor in bottom storage tank.
DHW tank bottom temperature39°C
Current temperature in the lower part of the DHW tank.
Collector pump runtime 1 h
Specifies the runtime of the collector pump.
Collector pump control 78%
Specifies the speed of the collector pump as a percentage of
maximum speed.
Setting value
Description
Desired
DHW tank temperature 60°C
When the specified temperature is reached in the DHW tank,
the DHW tank loading pump switches off.
Reload if DHW tank
temperature is below 45°C
Reloading of the DHW tank is authorised when the DHW tank
temperature is below this level.
repeatedly