B0430207 I
5
5.2 Inspection, cleaning and maintenance
Regular cleaning of the boiler extends its life and is a basic
requirement for smooth running. So clean the boiler regularly!
Recommended: When cleaning, use an ash vacuum.
5.2.1 Cleaning
The ash drawers (P4 Pellet 8-25) or ash container (P4 Pellet 32-100)
must be emptied at intervals according to energy requirements and
pellet quality. The grate and combustion chamber should also be
checked at these intervals for dirt.
WA R N I N G
Disposal of Ashes-
Ashes should be placed in a metal container with tight-fitting lid. The
closed container of ashes should be placed on a noncombustible floor
or on the ground, well away from all combustible materials, pending
final disposal. If the ashes are disposed of by burial in soil or
otherwise locally dispersed, they should be retained in the closed
container until all cinders have throughly cooled.
WA R N I N G
Solid-fuel burning appliances need to be cleaned frequently because
soot, creosote, and ash may accumulate. If there is a soot or creosote
fire, please do the following:
Establish a routine for the storage of fuel, care of the
appliance, and firing techniques.
Check daily for creosote build-up until experience shows how
often cleaning is necessary.
Be aware that the hotter the fire, the less creosote is
deposited, and that weekly cleanings may be necessary in mild
weather, even though monthly cleanings may be enough in the
coldest months.
Have a clearly understood plan to handle a chimney fire.
The chimney should be inspected periodically to determine if
creosote build-up has occurred. If a significant layer of
creosote has accumulated (3mm or more) it should be
removed to reduce the risk of a chimney fire.
A small and intense fire is preferable to a large smoldering one
to reduce the amount of creosote deposition.
Emptying the ash drawers (for P4 Pellet 8/15/20/25)
Open insulation
door
Open ash doors

Table of Contents

Other manuals for Froling P4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling P4 and is the answer not in the manual?

Froling P4 Specifications

General IconGeneral
ModelP4
CategoryBoiler
Fuel TypeWood Pellets
Automatic IgnitionYes
Automatic CleaningYes
Touchscreen ControlYes
Remote MonitoringYes
WeightVaries depending on model
Dimensions (H x W x D)Varies depending on model

Related product manuals