4.1.7 Operating Modes
Preparation
The boiler is ventilated, the sealing slider is opened and the Lambda
probe is heated.
Heating up
The combustion chamber is filled with pellets.
Pre-heating
The fan-assisted ignition switches on and the pellets are preheated until
a bed of embers is formed. For this period loading is deactivated.
Ignition
The pellets are ignited with the fan-assisted ignition. The flame is
distributed around the whole combustion chamber. The control of the
loading unit is defined as “Ignition” in the parameter menu.
Heating
The Lambdatronic controls combustion according to the boiler set-points.
Constant burn
The boiler has no power consumption. The ID fan and the loading unit
are deactivated.
Cleaning
The Lambdatronic carries out the cleaning program (duration approx. 3
min).
Shutdown wait
When the boiler is interrupted during the heating up procedures (heating
up, pre-heating, ignition), it waits for a specified period of time until the
next start attempt.
Shutdown wait 1
The ID fan runs to burn the remaining pellets.
The loading unit is deactivated.
Shutdown wait 2
The system is still ventilated by chimney draught. The loading unit is
deactivated.
Fault
CAUTION-Fault persists!
Procedure see Chapter 6-Troubleshooting
Burner Off
The Lambdatronic controls the connected heating components. All parts
of the boiler are deactivated.

Table of Contents

Other manuals for Froling P4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling P4 and is the answer not in the manual?

Froling P4 Specifications

General IconGeneral
ModelP4
CategoryBoiler
Fuel TypeWood Pellets
Automatic IgnitionYes
Automatic CleaningYes
Touchscreen ControlYes
Remote MonitoringYes
WeightVaries depending on model
Dimensions (H x W x D)Varies depending on model

Related product manuals