6.2 Blockage in ash discharge on the P4 Pellet
1. Shut down the system
2.
Remove the dustbin ⇨ See "Emptying the dustbin" [page 33]
1. Loosen the screws on the supporting post bracket (A)
The discharge pipe can now be rotated
1. Remove the cladding
2.
Push the lever to the side on the boiler up
3. Remove the ash transfer box from the boiler
6
Troubleshooting
Blockage in ash discharge on the P4 Pellet
38 Fröling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com