EasyManua.ls Logo

Fronius Primo GEN24 208-240 - AC Output and General Data

Fronius Primo GEN24 208-240
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AC output data
Max. output fault cur-
rent per duration
at 208 V
at 220 V
at 240 V
682 A/396 ms
676 A/120 ms
698 A/339 ms
Nominal output frequency 60 Hz
Setting range for mains frequency 45.0 - 66.0 Hz
Frequency trip limit accuracy 0.01 Hz
Total harmonic distortion < 3.0%
Power factor (cos phi)
0.8 - 1 ind./cap.
2)
Max. permitted mains impedance Zmax at PCC
(mOhm)
3)
None
General data
Maximum efficiency 97.6 %
CEC efficiency at 208 V
at 220 V
at 240 V
-
-
-
Cooling Controlled forced-air
ventilation
Protection class Type 4X
Dimensions H × W × D 23.0 × 20.8 × 7.1 inches
(583 x 529 x 180 mm)
Weight 49.05 lbs. (22.25 kg)
Shipping dimensions H × W × D 25.8 × 23.5 × 10.4 inches
(654 x 598 x 263 mm)
Shipping weight 57.10 lbs.(25.9 kg)
Inverter topology non-isolated, no trans-
former
Permitted ambient temperature -40 °F - +140 °F
(-40 °C - +60 °C)
Permissible humidity 0 - 100%
(incl. condensation)
EMC emission class B
DC/AC overvoltage category 2/4
Pollution degree 2
Safety class (according to IEC 62103) 1
Protection devices
DC isolation measurement Warning/shutdown at
RISO < 500 kOhm
DC overload performance Operating point shift,
power limiter
DC disconnector Integrated
DC reverse polarity protection Integrated
105

Table of Contents

Other manuals for Fronius Primo GEN24 208-240

Related product manuals