EasyManua.ls Logo

Fronius Primo GEN24 208-240 - Protection Devices and PV Point Output; Data Communication Specifications

Fronius Primo GEN24 208-240
120 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Protection devices
Arc Fault Circuit Interrupter AFCI type 1 integrated,
according to
UL1699B:2021 and F-I-
AFPE-1-4-1 according
to IEC63027:2023
Rapid shutdown Integrated, in accord-
ance with UL1741 and
CSA C22.2 No.330-23
RCMU Integrated
Active anti-islanding method Integrated
Behavior in the event of overheating Power limiter, active
cooling
Output data PV Point
Nominal AC voltage PV Point 1~NPE 120 V / 220 V /
240 V
Nominal output power
PV Point
at 120 V
at 220 V
at 240 V
1560 W
2860 W
3120 W
Max. continuous output
current
at 120 V
at 220 V
at 240 V
13.0 A
13.0 A
13.0 A
Nominal output frequency 63 Hz
Power factor
0 - 1 ind. / cap.
2)
Switching time <35 sec.
Data communication
WLAN SMA-RP connection
(FCC ID: QKWPILOT1 / IC ID: 12270-PILOT1 /
IFETEL:RCPFRTP20-1349) (FCC ID: QKWPI-
LOT2 / IC ID: 12270-PILOT2)
802.11b/g/n
(WPA, WPA2)
Ethernet (LAN) RJ 45, 10/100 Mbit
Wired shutdown (WSD) max. 28 devices/WSD
chain
max. distance
master → slave = 109
yd / 100 m
slave → slave = 109
yd /100 m
Modbus RTU SunSpec (2x) RS485 2-wire
Voltage level of digital inputs low: min. 0 V - max. 1.8
V
high: min. 4.5 V - max.
28.8 V
Input currents of digital inputs
depending on the input
voltage;
input resistance = 70
kOhm