Before commissioning
Proper use The cleaning device is to be used exclusively for cleaning Fronius robot welding torches,
especially the gas nozzle and its interior, in automatic mode and within the scope of the
technical data. Any use above and beyond this purpose is deemed improper. The manu-
facturer shall not be held liable for any damage arising from such usage.
Proper use includes:
- carefully reading these operating instructions
- following all the instructions and safety rules in these operating instructions
- performing all stipulated inspection and maintenance work
Operators, main-
tenance person-
nel
WARNING!
Risk of machines starting automatically.
This can result in serious injury and damage to property.
The device must only be used by 1 person at a time. It is also necessary to ensure
that no one else is within the working area of the device when the device is being
used.
The device must only be serviced by 1 person at a time. It is also necessary to
ensure that no one else is within the working area of the device when the device is
being serviced.
Setup regulations The cleaning device is tested to protection class IP 20, meaning:
- Protection against penetration by solid foreign bodies with diameters > 12.5 mm
(0.49 in.)
- No protection against the ingress of water
The device must not be set up and operated outdoors. The built in electrical parts must
be protected from direct wetting.
WARNING!
Danger from machines falling or toppling over.
This can result in serious injury and damage to property.
Always secure the cleaning device to the underlying surface.
Compressed air
supply specifica-
tions
To ensure that the cleaning device functions correctly, the following compressed air sup-
ply specifications must be met:
- Establish compressed air supply using a pressure limiter and compressed air filter
- Provide compressed air quality conforming to ISO 8573-1:2001, class 7 4 3, instru-
ment air
Solid particle concentration £ 10 mg/m
3
Vapour pressure dew point £ + 3°C
Oil concentration £ 1 mg/m
3
39
EN

Table of Contents

Other manuals for Fronius Robacta Reamer V Easy

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Robacta Reamer V Easy and is the answer not in the manual?

Fronius Robacta Reamer V Easy Specifications

General IconGeneral
BrandFronius
ModelRobacta Reamer V Easy
CategoryWelding System
LanguageEnglish

Related product manuals