If this area has to be accessed when setup and maintenance work is carried out, make
sure that
- the entire system is switched off for the duration of the work in this area
- and that it is prevented from starting up accidentally, e.g. as the result of a control
fault.
If untrained operators have access to the device, its compressed air supply must be dis-
connected for the duration of work in accordance with "Performance Level d" of the ISO
13849-1 standard.
In addition to these Operating Instructions, the safety rules issued by the robot manufac-
turer must also be observed.
Keep your body, especially your hands, face, hair, clothing and all tools away from mov-
ing parts, such as:
- rotating cleaning cutter
- upwards/downwards travelling cleaning motor
- extending/retracting gas nozzle clamping device
- wire cutter
Do not touch cleaning cutters immediately after use - risk of burns. Observe the special
safety rules in the Operating Instructions for handling cleaning cutters.
Protect hands, face and eyes against flying parts (shavings, etc.) and compressed air/
parting agent mixture escaping from the parting-agent injection nozzle.
Covers may only be opened/removed for the duration of any maintenance, installation or
repair work.
During operation
- Ensure that all covers are closed and fitted properly
- Keep all covers closed
Protecting your-
self and others
Anyone working with the device exposes themselves to numerous risks. In addition to
these Operating Instructions, the safety rules of the manufacturer of the entire welding
system must also be observed.
Keep all persons, especially children, out of the working area while any devices are in
operation or welding is in progress. If, however, there are people in the vicinity:
- Make them aware of all the dangers and health risks (crushing from mechanically-
powered parts, injury from cleaning cutter, flying shavings and similar matter, escap-
ing compressed air/parting agent mixture, flying sparks, dazzling by arc, inhaling of
harmful welding fumes, noise, possible danger from mains or welding current, etc.)
- Provide suitable protective equipment
- Alternatively, erect suitable safety screens/curtains
EMC Device Clas-
sifications
Devices in emission class A:
- Are only designed for use in industrial settings
- Can cause line-bound and radiated interference in other areas
Devices in emission class B:
- Satisfy the emissions criteria for residential and industrial areas. This is also true for
residential areas in which the energy is supplied from the public low-voltage mains.
EMC device classification as per the rating plate or technical data.
8

Table of Contents

Other manuals for Fronius Robacta Reamer V Easy

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Robacta Reamer V Easy and is the answer not in the manual?

Fronius Robacta Reamer V Easy Specifications

General IconGeneral
BrandFronius
ModelRobacta Reamer V Easy
CategoryWelding System
LanguageEnglish

Related product manuals